• Volume 2,Issue 4,2013 Table of Contents
    Select All
    Display Type: |
    • Influence of Targeted Muscle Reinnervation on Phantom Limb Pain and Distribution of Reinnervated Nerve in Rats

      2013, 2(4):3-7. DOI: 10.12146/j.issn.2095-3135.201307001

      Abstract (412) HTML (0) PDF 2.66 M (2451) Comment (0) Favorites

      Abstract:Targeted muscle reinnervation (TMR) can improve amputees’ movement ability by providing simultaneous and intuitive control of artificial limbs. However, little is known about whether TMR can relieve the phantom limb pain and how intramuscular nerve branches are distributed in the targeted muscle after the operation. The purpose of this study is to investigate the effects of TMR on phantom limb pain and to explore the possibility of post-operative neuranagenesis in rats. The rat model was established by sciatic nerves transaction (SNT group) and the proximal ends of these nerves were grafted into targeted muscles (TMR group). The degree of the phantom limb pain was measured by observing the autotomy behaviors of rats. The pilot results show that rats in the sham group have no autotomy behaviors, while rats in SNT group and TMR group show typical autotomy behaviors two days after the operations and the behaviors become worse gradually. However, the TMR group show obviously less pain than the SNT group. Meanwhile, some small new branches rising from the transferred nerves could be observed in targeted muscle with the aid of Sihler’s nerve staining technique. The experimental results suggest that TMR can possibly alleviate the phantom limb pain and the transferred nerve can regenerate to innervate with the targeted muscle.

    • Development and Evaluation of a Signal Acquisition System for the Movements of Upper Limbs in Nonhuman Primates

      2013, 2(4):8-13. DOI: 10.12146/j.issn.2095-3135.201307002

      Abstract (464) HTML (0) PDF 15.90 M (2204) Comment (0) Favorites

      Abstract:In this paper, a signal acquisition system was designed and developed for the movements of upper limbs of nonhuman primates. The system included a behavior-training unit of upper limbs and a myoelectric signal-acquisition unit. Two daily behaviors of feeding and drinking were employed to stimulate the motions of animals’ upper limbs for the convenience of the behavior training and signal acquisition. The feasibility of the training system was confirmed by the preliminary experiments on monkeys. Compared with the traditional systems, the system proposed in this study was more convenient for the signal acquisition of the arms of animals, and more suitable for nonhuman primates with different sizes.

    • Control System of Multifunctional Myoelectric Prostheses Using Microprocessor Unit

      2013, 2(4):14-19. DOI: 10.12146/j.issn.2095-3135.201307003

      Abstract (407) HTML (0) PDF 4.24 M (3990) Comment (0) Favorites

      Abstract:The applications of present commercially-available myoelectric prostheses are limited due to the difficulty in use and the long training time. The existing control methods can not realize natural controls of the prostheses. In this paper, a control system of multifunctional myoelectrical prostheses which contains a myoelectric-prosthesis controller based on a micro control unit and a multifunction prosthesis clinical training software, was designed and developed using a high-performance microprocessor. The pattern recognition of the electromyogram (EMG) was employed to determine the motion classes. Since the microprocessor is wearable, the system proposed in this study could possibly achieve flexible and natural controls of multifunctional myoelectric prostheses.

    • A Study of Different Linear Discriminant Analysis Methods in Myoelectric Prosthesis Control

      2013, 2(4):20-26. DOI: 10.12146/j.issn.2095-3135.201307004

      Abstract (452) HTML (0) PDF 9.07 M (2341) Comment (0) Favorites

      Abstract:When the surface electromyography (sEMG) signals change along with external or internal environment of the human body, general pattern classifiers will lead to a decrease of identification accuracy since they do not update their parameters adaptively. In order to adapt to the time-varying characteristics of sEMG signals, three kinds of adaptive algorithms for updating the parameters of a classifier during the use of artificial limb were introduced to improve the classification accuracy of time-variant sEMG signals. The pilot results of this study show that self-enhancing linear discriminant analysis is an effective solution and cycle substitution linear discriminant analysis presents the best performance but requires a large amount of calculations. The performance of the Kalman adaptive linear discriminant analysis is not prominent when it was used alone, and therefore it needs to be combined with other methods.

    • Development of a Wearable and Portable Rehabilitation Exoskeleton Robot

      2013, 2(4):27-31. DOI: 10.12146/j.issn.2095-3135.201307005

      Abstract (779) HTML (0) PDF 4.61 M (3153) Comment (0) Favorites

      Abstract:Robot-assisted rehabilitation which promises to redefine clinical strategies has drawn more and more attention for stroke therapy recently. Compared with classic rehabilitation limited to subjective observation of therapists on patients, the treatment by robotic devices can be more precise to improve the rehabilitation effects. In this paper, a wearable and portable rehabilitation robot with upper limbs of 5 degrees of freedom (DOFs) and upper limbs of 4 DOFs was introduced. The surface electromyographic (sEMG) signals were used to drive all the DOFs of both limbs to aid the training of prosthetic limbs. All data during the rehabilitation, including the sEMG signals and joint motions, can be collected for the purposes of both online analysis and offline storage.

    • Design and Implementation of a Training System of Hand Rehabilitation Based on Virtual Reality

      2013, 2(4):32-38. DOI: 10.12146/j.issn.2095-3135.201307006

      Abstract (439) HTML (0) PDF 3.98 M (4661) Comment (0) Favorites

      Abstract:The use of virtual reality technology in limb rehabilitation training could overcome the limitations of traditional rehabilitation methods, realizing the safe, comfortable and active rehabilitation training. In this paper, a rehabilitation training system based on virtual reality was designed for the recovery of impaired hand functions and evaluated in healthy projects. The training system was developed by using an interactive device, a human-computer interaction software and the virtual environment. The 5DT Data Glove 14 Ultra was used as the interactive device. The human-computer interaction software implemented with Visual Studio 2012 consisted of user management module, data collection module, classification module and real-time gesture recognition module. For the virtual environment (VR), a flash game was developed and used, which could be controlled by hand gestures through the communication between the VR environment and users. The proposed training system could be beneficial in improving the outcome of the hand function rehabilitation. Moreover, the use of flash games could improve the enthusiasm and initiative of the users effectively in rehabilitation training.

    • Visualization of Muscle Activities of Normal Swallowing Using High-Density Surface Electromyography Maps

      2013, 2(4):39-43. DOI: 10.12146/j.issn.2095-3135.201307007

      Abstract (442) HTML (0) PDF 4.80 M (3698) Comment (0) Favorites

      Abstract:This study aims to develop a new approach to visualize the global myoelectric activities related to normal swallowing in human. The high-density surface electromyography (sEMG) signals were recorded by a two-dimensional (2D) 96-electrodes array on the neck region while subjects were performing specified swallowing tasks. The root mean square (RMS) of the sEMG signals was calculated for the 96 channels to construct 2D sEMG maps of the muscle activities. Along the swallowing process, a series of 2D color sEMG maps were concatenated as a dynamic topographical video of swallowing. The dynamic high-density sEMG maps provided the spatial and temporal properties of the electrical muscle activity and presented the muscle contraction coordination which was closely related to the swallowing function. The exeprimental results of this pilot study from five normal subjects show that their sEMG maps represent the consistent patterns in the distribution of muscle activities along with a swallowing process. This might suggest that the dynamic swallowing sEMG maps would be a noninvasive means for visualizing swallowing process and evaluating swallowing function.

    • Effects of Low-frequency Electrical Stimulation on Sense and Motor Evoked Potentials of Healthy Adult Human

      2013, 2(4):44-48. DOI: 10.12146/j.issn.2095-3135.201307008

      Abstract (353) HTML (0) PDF 3.36 M (2736) Comment (0) Favorites

      Abstract:Objective: to observe the effects of low-frequency electrical stimulation (LES) on healthy adult with somatosensory evoked potential (SEP) and motor evoked potential (MEP). Method: 25 healthy adults (thirteen males and twelve females, with a mean age of 42.9 and a standard deviation of 5.7) participated in the study. SEP and MEP were measured before and after the LES stimulation. Results: After LES, the latency of SEP and MEP for the stimulated side became shorter and the amplitude became greater. These changes in latency and amplitude were statistically significant (P<0.05). For the unstimulated side, the changes of SEP and MEP did not show statistically significant difference. Conclusion: The SEP and MEP parameters, especially the amplitude, can be used to evaluate the effect of LES on central nervous system (CNS).

    • A Study of Transcranial Magnetic Stimulation Coil Positioning

      2013, 2(4):49-55. DOI: 10.12146/j.issn.2095-3135.201307009

      Abstract (999) HTML (0) PDF 1.50 M (12529) Comment (0) Favorites

      Abstract:Transcranial magnetic stimulation (TMS) is a non-invasive technique that can be used for brain studying and clinical therapy. Firstly, the technology feature and application of the TMS instrument were introduced. Then several TMS coil positioning methods were evaluated and several key problems about TMS coil positioning were discussed. The aim of this study was to propose a new method for TMS coil positioning. The new method combines three aspects of quantitative information including the brain scalp, brain anatomy and brain function and has great advantages and broad application prospects.

    • Current Research and Development Trend of Surface Drop Foot Stimulator

      2013, 2(4):56-60. DOI: 10.12146/j.issn.2095-3135.201307010

      Abstract (4217) HTML (0) PDF 1.64 M (11581) Comment (0) Favorites

      Abstract:Foot drop is the inability to voluntarily dorsiflex the ankle during the swing phase of gait and is usually caused by weakness and damages of the peroneal nerve. The consequences of the foot drop include the decreasing of gait quality, the limiting of mobility, the increasing of falling risk, and great increasing of energy expenditure during walking. Firstly biosignal sensors are used in the drop foot stimulator to detect foot movements. Then the surface drop foot stimulator produces a predefined stimulation profile to the peroneal nerve or tibialis anterial to elicit a dorsiflexion of the foot synchronized with the swing phase of gait to lift the foot. This paper reviewed the fundamentals and current researches of drop foot stimulators. Moreover, the development trends of the closed loop drop foot stimulator were also discussed in the paper.

    • Quick Detection of Hearing Loss Using Distortion Product Otoacoustic Emissions Evoked by Swept Tones

      2013, 2(4):61-67. DOI: 10.12146/j.issn.2095-3135.201307011

      Abstract (783) HTML (0) PDF 4.86 M (2640) Comment (0) Favorites

      Abstract:Distortion product otoacoustic emissions (DPOAEs) are sound energy generated by healthy inner ears when stimulated by two fixed-frequency pure tones. Since DPOAEs are physiologically related with the functional status of the inner ears, DPOAE measurement has been widely used in both hearing screening of newborns and hearing diagnoses of adults. However, there are some limitations in current measurements of DPOAE, such as complex operation, insufficient resolution and low efficiency. In this study, a new method in which frequency-varying swept tones were used to replace pure tones to evoke DPOAEs was proposed to overcome the limitations of current methods. In this method, a threeinterval paradigm was employed to eliminate the stimulus artifacts and a dynamic tracking filter was used to extract highquality swept-tone DPOAEs from the recorded signals. The results show that the swept-tone method can improve both the efficiency and frequency-resolution of current methods. Moreover, the swept-tone DPOAEs within a wide frequency range can help to identify the exact location of the hearing loss. Using swept tones to measure DPOAEs can be beneficial in developing a new type of OAE device with high efficiency to help doctors with accurate diagnoses and appropriate treatments in the clinic.

    • An Interactive Speech Training System with Virtual Reality Articulation for Hearing Impaired Mandarin-speaking Children

      2013, 2(4):68-73. DOI: 10.12146/j.issn.2095-3135.201307012

      Abstract (450) HTML (0) PDF 2.53 M (3178) Comment (0) Favorites

      Abstract:In this study, a novel interactive speech training system based on virtual reality articulation was introduced and its efficiency in the rehabilitation of hearing impaired (HI) children was investigated as well. 20 meaningful words in Mandarin were presented by using a 3D talking head in this system for articulatory training. The Electro-Magnetic Articulography (EMA) and graphic transform technology were used to develop the reality inner articulatory movements of 3D talking head. Furthermore, relevant corpus was organized in a listening module and a speaking module of the system to help to recover the HI children’s language skills. Then, the accuracy of virtual reality (VR) articulatory movement model was evaluated through a series of experiments. Finally, a pilot test was performed on the training of two HI children with the system. The preliminary results show that there is an improvement in the speaking abilities of the tested HI children. Meanwhile, the system was recognized as acceptable and interesting for younger children. The study indicates that the presented training system is effective to articulation training for the HI children.

    • Brief Analysis of the Development of Rehabilitation Medicine and Equipment

      2013, 2(4):74-78. DOI: 10.12146/j.issn.2095-3135.201307013

      Abstract (337) HTML (0) PDF 5.53 M (4074) Comment (0) Favorites

      Abstract:With the rapid development of rehabilitation medicine and modern technology, rehabilitation medicine and equipment are becoming more and more advanced and sophisticated. Up to now, a lot of new technologies have been introduced into the rehabilitation field, such as virtual reality, computer networks, software engineering, and mechanical engineering. Combining the theoretical basis of rehabilitation medicine and national policies about rehabilitation, the authors analyzed the current status and future directions of the development of rehabilitation medicine and equipment from the following perspectives: technology integration, the fineness of function division, user-friendly design and medical informatization.

    • A Health Surveillance Terminal Based on Android Smart Phone

      2013, 2(4):79-82. DOI: 10.12146/j.issn.2095-3135.201307014

      Abstract (391) HTML (0) PDF 8.70 M (4276) Comment (0) Favorites

      Abstract:The growing popularity of mobile communications and intelligent computing technology provides a wide range of opportunities for mobile medical applications. In this paper, an Android-based mobile terminal was designed and implemented to monitor the physiological parameters of human bodies. Wireless bluetooth technology was used for the communication between the sensor and the mobile terminal to form a body sensor network. The practical applications show that the terminal can help the patients with their physiological monitoring, diagnostics and health management.

Current Issue


Volume , No.

Table of Contents

Archive

Volume

Issue

Most Read

Most Cited

Most Downloaded

Baidu
map